| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : KAIXIANG
Model Number : AC400-1000KVA
Certification : ISO9001
Place of Origin : CHINA
MOQ : 1 set
Price : negotiable
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 15 Sets per Month
Delivery Time : Within 30 working days
Packaging Details : Wooden Case for Load bank
Casing Dimensions and Cooling : about 4000*2350*2591mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling
Transportation : Hoisting, there are lifting lug in top of casing
Casing Color : Grey(RAL7035)
Ambient Temperature : -10℃~+50℃
Voltage range : AC400v 50hz ±10%
Display Precision : 0.5 class
 
AC Genset Load Bank 1000KVA Load Bank Cabinet Grey Casing Color
 
Product description
 
Manufacturers of small gas engines also use load banks to test newly manufactured engines under various mechanical loads. This is accomplished by connecting the engine to the load bank via a device called a dynamometer. Again, engine performance is monitored and, if necessary, adjustments are made to ensure the product performs within intended specifications.
 
Technical Parameter 
 
| Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, | 
| Voltage range | 400v 50hz ±10% | 
| Max Rated power | Apparent Power: 1000kVA | 
| Load Resolution | Resistive load:1.2.2.5.10.10.20.50.100.200.200.200kw | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | AC380VAC/50Hz,3 phase 4 wire | 
| Wire Connection | Load power supply input——Copper bar (star coupling) | 
| Communication Interface | RS485, | 
| Casing Dimensions and Cooling | about 4000*2350*2591mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 3600kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤1500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
 
Product Advantage
 
1.User can press the emergency stop button in the panel to unload immediately when the load bank is abnormal while working.
2.Over-load: Automatic load dump and give alarm when voltage is over safety thresholds.
3.Short Circuit Protection: Fuse could avoids damage to equipment when short circuit or current overload.
4.Fan protection: Machine could not do load testing before working power of fan is on.
5.The machine will unload and give alarm when any fan is abnormal or with insufficient air volume, etc.
 
Application 
 
1.Manufacturers of small gas engines also use load banks to test newly manufactured engines under various mechanical loads.
2.This is accomplished by connecting the engine to the load bank via a device called a dynamometer.
3.engine performance is monitored and, if necessary, adjustments are made to ensure the product performs within intended specifications.
 
|   | 
| AC Genset Diesel Generator Load Bank Cabinet With 0.5 Class Display Precision Images | 
 Yellow Apparent Power Capacitive Load Bank Local Control With 3 Phase 4 Wire
                                                                                    
                        
                        
                        
                                                            Yellow Apparent Power Capacitive Load Bank Local Control With 3 Phase 4 Wire
                                                    
                        
                     400 V 1375 Kva Inductive Load Bank Grey With 86~106 KPa Atmospheric Pressure
                                                                                    
                        
                        
                        
                                                            400 V 1375 Kva Inductive Load Bank Grey With 86~106 KPa Atmospheric Pressure
                                                    
                        
                     Three Phase Output Ups Load Bank , Ocean Engineering Resistance Load Bank
                                                                                    
                        
                        
                        
                                                            Three Phase Output Ups Load Bank , Ocean Engineering Resistance Load Bank
                                                    
                        
                     Custom Design Inductive Load Bank Apparent Power For Testing Output Power
                                                                                    
                        
                        
                        
                                                            Custom Design Inductive Load Bank Apparent Power For Testing Output Power
                                                    
                        
                     Accurate Test Hoisting Automatic Load Bank Remote Control For Malaysia
                                                                                    
                        
                        
                        
                                                            Accurate Test Hoisting Automatic Load Bank Remote Control For Malaysia
                                                    
                        
                     1100KW Inductive Load Bank , 1375 KVA Office Buildings Three Phase Load Bank
                                                                                    
                        
                        
                        
                                                            1100KW Inductive Load Bank , 1375 KVA Office Buildings Three Phase Load Bank
                                                    
                        
                     Multifarious Voltage Reactive Load Bank High Power For Customer Choose
                                                                                    
                        
                        
                        
                                                            Multifarious Voltage Reactive Load Bank High Power For Customer Choose
                                                    
                        
                     1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection
                                                                                    
                        
                        
                        
                                                            1500 KVA 1200KW Inductive Load Bank Resistive With Short Circuit Protection
                                                    
                        
                     Intelligent / Remote Control AC Load Bank , Robust Water Cooled Load Bank
                                                                                    
                        
                        
                        
                                                            Intelligent / Remote Control AC Load Bank , Robust Water Cooled Load Bank
                                                    
                        
                     Resistive Power Capacitive Load Bank 3630 Kvar For Generator Testing
                                                                                    
                        
                        
                        
                                                            Resistive Power Capacitive Load Bank 3630 Kvar For Generator Testing