| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : KAIXIANG
Model Number : 1200KW
Certification : ISO9001
Place of Origin : HEBEI CHINA
MOQ : ONE SET
Price : negotiable
Payment Terms : L/C, D/A, D/P, D/P, T/T, Western Union, MoneyGram, D/P
Supply Ability : 20 SETS ONE MONTH
Delivery Time : ONE MONTH AFTER GET DEPOSIT
Packaging Details : WOODEN CASE
Rating Voltage : 440VAC/50Hz, 3 phase 4 wire, line voltage 440V, phase voltage 254V
Rated Voltage : 440 VAC
Installed Capacity : Resistive load: 1200 kW
Control Power : 690 VAC / 50 Hz
size : 1600*2600*2000mm
weight : 1700kg
For Diesel Generator Automatic Remote Control 440V 1200K Watt AC Load Bank
 
Product Description
AC440-1200kW Automatic Load Bank is mainly used to test the performance of generator. It can provide scientific monitor measure for generating set equipment.
Technical Parameters
| Rating Voltage/Frequency | 440VAC/50Hz, 3 phase 4 wire, line voltage 440V, phase voltage 254V | 
| Rated Load Power | Resistive load: 1200kW | 
| Installed Capacity | Resistive load: 1200kW | 
| Load Step | 1,2,2,5,10,10,20,50,100,200,200,200,200, 200kW, min step load: 1kW | 
| PF(Power Factor) | 1 | 
| Load Tolerance (each step) | ±5% | 
| Load Tolerance(overall) | ±3% | 
| Display Precision | 0.5 class | 
| Control Power | 380VAC/50Hz 3 phase 4 wire (line voltage 380V, phase voltage 220V ) | 
| Wire Connection | Load power supply input——Copper bar (star coupling) Control power supply input——Connector-bar | 
| Insulation | F | 
| Protection Grade | IP21 | 
| Way of Working | Continuous Working | 
| Casing Dimensions and Cooling | about 1600*2600*2000mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling | 
| Weight | About 1700kgs/set | 
| Transportation | Hoisting, there are lifting lug in top of casing | 
| Casing Color | Grey(RAL7035) | 
| Ambient Temperature | -10℃~+50℃ | 
| Relative Humidity | ≤95% | 
| Altitude | ≤2500 meter | 
| Atmospheric Pressure | 86~106kPa | 
| Contactor | Schneider | 
| Fuse | DELIXI | 
| MCU | INFINEON | 
| Data processing software | Kaixiang(self-developed) | 
| Alloy Resistance | Kaixiang(self-developed) | 
Product Advantage
 
1. Real-time Monitor: through software display main parameter value, such as voltage, current, power, power factor, frequency and time.
2. Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.
3. Data Collection Interval: the minimum data resolving time is 2s.
4.Data save and query: all the test data is saved in the software, easy to query in the history testing data.
Application
 
1. for generator power ,the frequency,the voltage,the current,power factor and other generator parameters
2. Because Most of the generator use the diesel oil,which can cause the fuel oil unfilled,carbon deposition ,complete machine efficiency reduced when the diesel oil load is lower than 50% or in idling situation for a long time and even cause starting difficulty ,power insuffciency,oil consumption increased,finally,opening the cylinder for maintenance too early and the abandonment ,so the load bank will be generator's ideal false load.

 
 
|   | 
| 1200 KW Resistive Load Bank Calculation Continuous Working For Generator Images | 
 Three Phase Resistive AC Load Bank Eliminate Carbon Deposition Of Generator
                                                                                    
                        
                        
                        
                                                            Three Phase Resistive AC Load Bank Eliminate Carbon Deposition Of Generator
                                                    
                        
                     Dummy AC 1000kw Resistive Load Bank Testing For Generator To 5MW ISO9001
                                                                                    
                        
                        
                        
                                                            Dummy AC 1000kw Resistive Load Bank Testing For Generator To 5MW ISO9001
                                                    
                        
                     High Power Density 3 Phase Load Bank Electrical Load Testing Equipment With
                                                                                    
                        
                        
                        
                                                            High Power Density 3 Phase Load Bank Electrical Load Testing Equipment With
                                                    
                        
                     3 Phase Generator Dummy Ups Load Bank Test Electrical With High Accuracy
                                                                                    
                        
                        
                        
                                                            3 Phase Generator Dummy Ups Load Bank Test Electrical With High Accuracy
                                                    
                        
                     ISO IEC CE Electronic Portable Resistive Load Bank With F Insulation
                                                                                    
                        
                        
                        
                                                            ISO IEC CE Electronic Portable Resistive Load Bank With F Insulation
                                                    
                        
                     Auto Testing Machine Usage AC 1000KW Reactive Load Bank Continuous Duty Cycle
                                                                                    
                        
                        
                        
                                                            Auto Testing Machine Usage AC 1000KW Reactive Load Bank Continuous Duty Cycle
                                                    
                        
                     Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die
                                                                                    
                        
                        
                        
                                                            Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die
                                                    
                        
                     Wirewound Technology Resistance AC Load Bank 1000KW For Data Center Testing
                                                                                    
                        
                        
                        
                                                            Wirewound Technology Resistance AC Load Bank 1000KW For Data Center Testing
                                                    
                        
                     High Load Power Density Generator Load Bank 500kw Grade Orange Testing UPS
                                                                                    
                        
                        
                        
                                                            High Load Power Density Generator Load Bank 500kw Grade Orange Testing UPS
                                                    
                        
                     High Accuracy Electrical Generator Resistive Load Tester 100kw Power
                                                                                    
                        
                        
                        
                                                            High Accuracy Electrical Generator Resistive Load Tester 100kw Power